FWA and DWA: how much the ship rises in salt water
FWA = Δ/(4·TPC) in millimetres; for an intermediate density, DWA = FWA·(1.025 − ρdock)/0.025.
MetaCAD Live Notebook
fresh-water-allowance-v1Change displacement, TPC and dock-water density. The model shows by how many millimetres the load line may be submerged in port so the ship floats exactly at her marks in sea water.
DWA for this water: 125 mm
Model range: 2,000 — 250,000 t. Arrow-key step: 500 t
Model range: 5 — 150 t/cm. Arrow-key step: 0.5 t/cm
Model range: 1 — 1.025 t/m³. Arrow-key step: 0.001 t/m³
From the initial example: 0 mm
Linear near the waterline: TPC is held constant over the draft change and density is treated as uniform. Real TPC varies with draft; for cargo operations use the ship’s hydrostatic tables and a hydrometer density sample.
Other inputs held fixed. Diamond = current example.
Current: 1.01 t/m³ → 125 mm
Chart data
| Dock water density (t/m³) | DWA for this water (mm) |
|---|---|
| 1 | 208.333 |
| 1.003 | 182.292 |
| 1.006 | 156.25 |
| 1.009 | 130.208 |
| 1.01 ◆ | 125 |
| 1.013 | 104.167 |
| 1.016 | 78.125 |
| 1.019 | 52.083 |
| 1.022 | 26.042 |
| 1.025 | 0 |
The allowance is linear in the density difference: a ship loaded DWA deeper than her marks in brackish water rises exactly back to them in 1.025 t/m³ water — the same weight displaces a larger volume of lighter water.
FWA = Δ / (4·TPC); DWA = FWA · (1.025 − ρdock) / 0.025Δ is displacement in tonnes, TPC in tonnes per centimetre of draft, ρ in t/m³; FWA and DWA come out in millimetres.
Primary result substitution
25000 / (4 × 30) × (1.025 − 1.01) / 0.025 ≈ 125 mm- Displacement
- 25,000 t
- TPC at the waterline
- 30 t/cm
- Dock water density
- 1.01 t/m³
Keep or share this example
One saved example per lesson, no account. The share link includes your inputs only when you choose “Copy link”.
Why may the mark go deeper in 1.010 t/m³ dock water?
Model limits
Linear near the waterline: TPC is held constant over the draft change and density is treated as uniform. Real TPC varies with draft; for cargo operations use the ship’s hydrostatic tables and a hydrometer density sample.
Change displacement, TPC and dock-water density. The model shows by how many millimetres the load line may be submerged in port so the ship floats exactly at her marks in sea water.
What to notice
The allowance is linear in the density difference: a ship loaded DWA deeper than her marks in brackish water rises exactly back to them in 1.025 t/m³ water — the same weight displaces a larger volume of lighter water.
Where the teaching model ends
Linear near the waterline: TPC is held constant over the draft change and density is treated as uniform. Real TPC varies with draft; for cargo operations use the ship’s hydrostatic tables and a hydrometer density sample.
Formulas
FWA = Δ / (4·TPC); DWA = FWA · (1.025 − ρdock) / 0.025How to use the notebook
Start with the worked scenario, change one slider, and follow the metrics and plot. Then answer the checkpoint. A number without its stated model boundary is not treated as a conclusion.
Try it in a calculator
Questions
FAQ
Can this result be used for a shipboard operation?
What stays fixed when a slider moves?
Related lessons
Want the whole system, not single topics?
MetaCAD Academy — training with live calculators and worked examples on real ships.
Browse coursesSources & method
- — Derrett, Ship Stability for Masters and Mates — fresh water allowance and dock water allowance.
- — International Convention on Load Lines 1966/1988 — zones and allowances.
- — MetaCAD deterministic educational model; equation and assumptions are displayed with the result.
- — The vessel’s approved data and operating procedures remain the controlling source for operational decisions.
MetaCAD educational material. An independent professional review of this lesson has not yet been claimed.